SPECIFICATIONS
MODEL TC1015-2
DC PROPORTIONAL TEMPERATURE CONTROLLER |
|
OUTPUTS:
OUTPUT 1:
OUTPUT 2:
OUTPUT 3: |
Block heater output
Component heater output
The channel provides an audible, visual and contact closure alarm when preset temperature is above or below a limit. This limit is selected for +/- 1 degree or +/- 10 degrees or by defeat alarms via a front panel three position switch. |
OUTPUT VOLTAGES:
OUTPUT 1:
OUTPUT 2: |
DC
DC |
OUTPUT POWER:
OUTPUT 1:
OUTPUT 2: |
60 Watts
15 Watts |
SENSOR SET POINT RESISTANCE:
BLOCK CHANNEL:
SENSOR CHANNEL: |
Nominal 470 ohms at 0 degC
Nominal 595 ohms at operating temperature 68 deg C. |
NOTE: Sensor and resistance balance arm will both be physically located on unit under control. |
SET POINT STABILITY:*
Vs. TIME:
Vs. TEMP: |
+/-0.1 deg C/24 hrs @ constant temperature.
+/-0.05 deg/deg C |
| HUM AND NOISE: |
No frequencies of 100KHz or greater shall be generated by the controller with the controlled system on the fine heater or sensor lines. |
| AMBIENT TEMPERATURE: |
15 deg C to 50 deg C |
| INPUT POWER: |
115V +/-10V, 60Hz |
FRONT PANEL METERS:
1. Component temperature deviation meter
2. Block heater hi/low temperature meter
3. Fine Heater Indicator (white) |
FRONT PANEL CONTROLS:
1. Two Range Monitor Sensitivity Switch:
Range I: +/- one degree sensitivity
Range II: +/- ten degree sensitivity |
2. Low Alarm Set Switch:
Position 1: OFF
Position 2: 1 degree
Position 3: 10 degrees |
3. High Alarm Set Switch:
Position 1: OFF
Position 2: 1 degree
Position 3: 10 degrees |
FRONT PANEL INDICATORS:
1. High Temperature RED indicator
2. Low Temperature GREEN indicator |
| PHYSICAL: |
8.75 maximum standard 19" Rack panel mount. |
   |